Sinus Units

Cascades

  • As HydroFixx or standard cascade
  • The heating boilers are connected by means of 90°pipe bends directed to the rear such that all boiler models and sizes can be installed.

Multiple temperature zone low loss header

  • From 12.0 m³/h up to 400.0 m³/h
  • Low loss header, heating manifold and buffer tank in one
  • A comprehensible, well-arranged system design
  • Space-saving and modular

Multi-zone manifold

  • Increase in efficiency of the entire heating system
  • Optimum hydraulics in all operating states
  • Clear added value for your boiler systems due to the Sinus multi-zone heating manifold
  • Optimum use of condensing boiler technology, i.e. high degree of efficiency of condensing boiler technology due to minimum return temperature

Module unit

  • From 10.8 m³/h up to 391.0 m³/h
  • Compact unit consisting of low loss header, 90° pipe bends and heating manifold
  • Optimum hydraulics in all operating states

Multiple temperature zone hydraulic separator

The multiple temperature zone low loss header consists of a low loss header (DN 150 up to DN 700) and several compact manifolds (80/60 up to 700/500).

go to product

Module units

Module unit, consisting of low loss header and compact manifold in modular design.
Low loss header made of hollow square profile S235 with welded-in top and bottom.
2" threaded connector for desludging and 1/2" sleeve for temperature sensor.
Pedestal with oblong holes for attachment to the floor.
Compact manifold as combined flow and return manifold with chambers arranged adjacent to each other, separated by sinusoidal partition wall, made of black sheet steel S235. Direct connection to the respective return lines. Operating pressure max. 6 bar, operating temperature max. 110°C.

go to product

Standard cascade

Manifold / Collector pipe for the accommodation of the boiler connections made of two section tubes on top of each other, material S235 with welded-in end caps and 3/4" drain connection couplings.
A low loss header is firmly attached as a unit to the manifold / collector pipe on the left-hand or right-hand side, depending on the type of installation. Fixed pedestal in standard design with an overall height of 200 mm. The cascade unit is pressure-tested at 9 bar and primed at the factory. Application range: Operating temperature up to max. 90°C, operating pressure up to max. 6.0 bar.
Low loss header made of hollow square profile S235 with two lateral nozzles for the connection of the secondary heating circuits.

go to product

HydroFixx cascade

Cascade including hydraulic separator

Combined flow and return manifold with chambers arranged adjacent to each other, separated by sinusoidal partition wall, with directly incorporated, flat, horizontally welded-on hydraulic separator for use on the primary side directly beneath the heating boilers. Consisting of square profiles S235,
wall thickness 4 mm, with two lateral nozzles for the connection of the
secondary heating circuits. The HydroFixx cascade is pressure-tested and primed
at the factory. Operating pressure max. 6 bar. Operating temperature max. 110°C.

go to product

Multi-zone manifold

The special feature of the manifold-hydraulic separator combination is the division into three
temperature zones, combined with integrated hydraulic separator to avoid
interaction. In normal operating mode, the combination of high-temperature and low-temperature
circuit ensures the desired minimum return temperature,
which operates the condensing boiler within the condensation range. The result: High
degrees of efficiency are reached, because the quantity of heat contained in the heating water
can be used in the best possible way.